Suppose we have two people sealed off in a very narrow area (after a collapse in a mine, for the record). How long, approximately, until they start suffocating? (actually, until they can feel the lack of air)

Narrow= they almost can't move

[This message has been edited by Silver3 (edited October 19, 2004).]


Posts: 1075 | Registered: Sep 2004  | Report this post to a Moderator
Magic Beans
Member
Member # 2183

 - posted      Profile for Magic Beans   Email Magic Beans         Edit/Delete Post 
A quick Internet search (which you could have done ) revealed the material quoted below:
quote:

The issue of suffocating in an enclosed space is not one of running
out of oxygen; it's one of being poisoned by carbon dioxide -- CO2.
CO2 becomes toxic at a concentration of 1%. (Normal atmospheric
concentration is 0.036 percent (360 ppmv).) A concentration of 10% can
cause respiratory paralysis and death within a few minutes.

How fast the CO2 level builds depends on how fast you produce it. This
would be related to how fast you are breathing. At rest you would
exhale much less than if you were exercising.

Given that a moderately active or stressed person produces about 1.7
cubic feet of CO2 per hour and assuming a concentration of 3% CO2 is
the highest safe limit, here is an equation you can use to calculate
how long a given number of people can stay in a given space before
toxic levels of CO2 build up ---

T = Number of hours of air in a sealed room


(Volume of air inside the room in cubic feet) x (3% or 0.03)
T = ---------------------------------------------------------
(Number of people) x (one person's hourly production of CO2)


Scroll down this page for explanation of that equation

FOR YOUR SAFETY - Sealed Room Atmosphere
http://yahweh.com/News/07_2002/NL7-02.html


So….using the Google calculator –

Your room of 10x10x2 meters would be –

200 (cubic meters) = 7 062.93334 cubic feet.

Let's call that 7000 cubic feet.

T = (7000 x .03) / (1 x 1.7) = 210/1.7 = 123.5 hours.


------------

From a Science Fiction author ---

"As it turns out, a 10 X 10 X 10 foot space, or 1,000 cubic feet, will
be filled with a lethal concentration of CO2 by one resting human
sized individual in just 24 hours. (The CO2 level reaches about 1% in
that time). Moderate activity will cut this time to 12 hours, and
strenuous activity to 6 hours."

Suffocation, CO2 poisoning
http://www.frontiernet.net/~jamesstarlight/Suffocation.html

Let's check that with our equation ----

(1000 x .01) / 1.7 = 17 hours. Close.

----------------

This website addresses oxygen depletion, but ignores CO2
concentrations, which makes their answer to the question, "How long
can we survive in an enclosed space?" entirely wrong.

I include it because I suppose these equations would be useful if you
were using up air in the room, but exhaling out through a tube or if
you employed air scrubbers to remove the CO2.

Question: How long can 10 healthy adult people survive in a sealed
room of dimensions 3m x 4m x 2.5m before they run out of oxygen (i.e.
the oxygen concentration drops to 12%)? An adult of average weight
consumes about 3.33 10-6 m3 s-1 of oxygen while at rest. The typical
volume of an adult is 0.1 m3.

Answer: The equation for rate of change of oxygen concentration in an
enclosure without oxygen replacement (neglecting the buildup of carbon
dioxide) is:

(total oxygen consumption rate) = (volume of oxygen consumed) / (total
time lapsed)

or : nC = {Vr - nVp}{Li - Lf}/t

[see explanations here]

How long can we survive in a sealed enclosure?
http://www-das.uwyo.edu/~geerts/cwx/notes/chap01/ox_exer.html

---------------------
A hypothetical question to a Biosphere scientist --

"[an adult] would need about 350 litres of oxygen per day (the amount
of oxygen in 1.7 cubic metres of air)."


Biosphere
http://www.newscientist.com/lastword/article.jsp?id=lw564

-----------------

Safety Information for Cavers (Spelunkers) – this is a good table that
shows the stages of Co2 poisoning at different concentrations [scroll
down]

CARBON DIOXIDE, CAVES AND YOU
Table 2. Generally accepted physiological effects of CO2 at various
concentrations by volume
http://wasg.iinet.net.au/Co2paper.html


The URL is: http://answers.google.com/answers/threadview?id=258239

Good luck!


Posts: 284 | Registered: Sep 2004  | Report this post to a Moderator
Silver3
Member
Member # 2174

 - posted      Profile for Silver3   Email Silver3         Edit/Delete Post 
Thanks. I'll do the maths. (Sigh)
Posts: 1075 | Registered: Sep 2004  | Report this post to a Moderator
Beth
Member
Member # 2192

 - posted      Profile for Beth   Email Beth         Edit/Delete Post 
Wow, that was all really interesting. Thanks for posting it!
Posts: 1750 | Registered: Oct 2004  | Report this post to a Moderator
Survivor
Member
Member # 213

 - posted      Profile for Survivor   Email Survivor         Edit/Delete Post 
Really, the variables in a situation like you describe are far too great to yield to simple calculations. Particularly underground, where other gases can be seeping into the air from the soil/rock/whatever.

If it is narrow enough that they can't move, then it could still be that they have air circulation. On the other hand, it could be that all breathable air has been removed by the collapse or that toxic gases have been introduced (possibly from a "gas pocket", a common and real danger in mines).

So depending on various circumstances, the time before they start "running out of air" could be anything from zero to infinity after a serious cave-in. Make up a number, establish a cause, and that's your answer.


Posts: 8322 | Registered: Aug 1999  | Report this post to a Moderator
bladeofwords
Member
Member # 2132

 - posted      Profile for bladeofwords   Email bladeofwords         Edit/Delete Post 
That was very interesting. I always thought it was just running out of air. Anybody know off the top of their head what the effects of the poisoning look like?

Jon


Posts: 175 | Registered: Jul 2004  | Report this post to a Moderator
dspellweaver
Member
Member # 2133

 - posted      Profile for dspellweaver           Edit/Delete Post 
Magic Beans, what search words did you use to bring up these results?
Posts: 45 | Registered: Jul 2004  | Report this post to a Moderator
Magic Beans
Member
Member # 2183

 - posted      Profile for Magic Beans   Email Magic Beans         Edit/Delete Post 
http://www.google.com/search?q=oxygen+consumption+in+enclosed+space
Posts: 284 | Registered: Sep 2004  | Report this post to a Moderator
dspellweaver
Member
Member # 2133

 - posted      Profile for dspellweaver           Edit/Delete Post 
Thank you
Posts: 45 | Registered: Jul 2004  | Report this post to a Moderator
Survivor
Member
Member # 213

 - posted      Profile for Survivor   Email Survivor         Edit/Delete Post 
The effects of toxic gases in an enclosed area will vary depending on the type of gas, naturally. But it is pretty common for CO2 to collect in underground areas for a variety of reasons. That would have about the same effect as "running out of air". Many other gasses would have similar effects, in low concentrations.

If the concentrations are high, then usually you just start coughing and keel over after a few seconds. But you don't always get a chance to cough first.


Posts: 8322 | Registered: Aug 1999  | Report this post to a Moderator
   

   Close Topic   Feature Topic   Move Topic   Delete Topic next oldest topic   next newest topic
 - Printer-friendly view of this topic
Hop To:


Contact Us | Hatrack River Home Page

Copyright © 2008 Hatrack River Enterprises Inc. All rights reserved.
Reproduction in whole or in part without permission is prohibited.


Powered by Infopop Corporation
UBB.classic™ 6.7.2